5462-966 Woodward overspeed protector
The 5462-966 is a microprocessor-based digital governor controller produced by Woodward, belonging to its classic 505 series.
It is primarily designed for speed control and protection of steam turbines. Below is a detailed introduction to this product:
I. Product Overview
- Brand and Model: Woodward 5462-966
- Series: 505 Series Digital Governor
- Type: Microprocessor-based controller
- Purpose: Specifically designed for steam turbines to control their speed and provide overspeed protection.

II. Core Functions
- Speed Control:
- 5462-966 Precisely controls the speed of steam turbines by adjusting steam inlet flow.
- Supports single-range or split-range actuators to accommodate turbines of different sizes.
- Overspeed Protection:
- Incorporates triple independent overspeed protection logic to ensure rapid shutdown in case of overspeed, preventing equipment damage.
- Provides an overspeed test button for convenient on-site testing of protection functions.
- Emergency Shutdown:
- Equipped with an emergency stop button for immediate shutdown in emergency situations.
- System Protection:
-
- Automatically switches control modes upon sensor failure to ensure uninterrupted system operation.
- Offers local/remote control priority selection to adapt to different operational scenarios.

-
A DMA controller is actually an interface circuit between peripheral devices using DMA and the system bus. This interface circuit is
composed of an interrupt interface and a DMA mechanism. Traditionally, DMA interface circuits are referred to as DMA controllers.
Composition of DMA Controller
(1) Memory address counter: used to store the address of data to be exchanged in memory. Before DMA transfer, the starting position
(first address) of data in memory must be sent to the memory address counter through a program. When DMA transfers, for each data exchange,
the address counter is incremented by “1” to incrementally provide the address of the batch of data to be exchanged in memory.
(2) Word counter: used to record the length (number of words) of the transmitted data block. Its content is also pre-set by the program before
data transmission, and the number of exchanged words is usually represented in the form of complement codes. During
DMA transfer, the word counter increments by “1” for each word transferred. When the counter overflows and a carry is generated at the highest bit,
it indicates that the batch of data has been transferred, causing the DMA controller to issue an interrupt signal to the CPU.
(3) Data buffer register: used to temporarily store the data (one word) transferred each time. When input, it is sent to the data buffer register by the device
(such as a disk), and then sent to the memory through the data bus by the buffer register. On the contrary, when outputting, it is sent from memory to the
data buffer register through the data bus, and then to the device.
III. Technical Specifications
- Power Supply: 18-32 VDC, supporting 24VDC input.
- Display: Two-line x 24-character LED display for clear indication of operating status and parameters.
- Enclosure: NEMA 4X or IEC 60529 IP56 rated for protection against harsh industrial environments.
- Inputs/Outputs:
- Inputs: 6 programmable current inputs, 16 discrete contact inputs.
- Outputs: 2 actuator outputs, 8 relay outputs, 6 programmable current outputs.
- Communication Interfaces: 5462-966 Supports RS-232, RS-422, and RS-485 hardware interfaces for easy integration with host computers or other devices.
- Software: Equipped with OpView™ and 505View software for parameter configuration, monitoring, and fault diagnosis.
- Operating Temperature: -20 to +60°C (some models support -4 to +140°F).
- Storage Temperature: -40 to +85°C (some models support -40 to +185°F).
- 5462-966 Weight: Approximately 9.11 pounds (4.13 kilograms).
IV. Application Scenarios
- Steam Turbine Control: 5462-966Suitable for steam turbines of various sizes, including industrial steam turbines, small grid turbo-generators, and turboexpanders.
- Single Extraction and Admission Applications: Designed for operating steam turbines in single extraction and/or admission applications.
- On-Site Programming: Allows on-site operators to program and adjust parameters through an integrated operator control panel, adapting to different operating conditions.
V. Product Advantages
- High Reliability:
- Microprocessor-based design ensures precise control and stability.
- Triple independent overspeed protection logic provides multiple layers of safety.
- Flexibility:
- Supports various actuator and sensor configurations to accommodate different turbine models.
- Offers a rich set of input/output interfaces for easy system expansion and integration.
- Ease of Use:
- Two-line x 24-character LED display provides an intuitive operating interface.
- A 30-key multifunctional keyboard simplifies parameter configuration and operation.
- Compatibility:
- Supports multiple communication protocols for easy integration with DCS, PLC, and other systems.
- Provides OpView™ and 505View software for remote monitoring and fault diagnosis.
Woodward ship parts module debugger controller actuator generator set
8272-582 Woodward overspeed protector,
9907-1200 Woodward ProTech 203,
5417-413 Woodward turbine controller,
5437-418 Woodward turbine controller,
5462-521 Woodward turbine controller,
PROTECH203 Woodward overspeed protector,
5461-644 H WOODWARD Debugger unit,
1785-655 Woodward speed control module,
8280-419 WOODWARD Debugger unit,
5466-026 Woodward overspeed protector,
Parker ASML 4022.631.24391 RH-PU Mk3 SEM-I-557=9A39
ASML 4022.428.10970 Voltage Current PCB Card 4022.428.1097 PAS 50002500
HP AGILENT 5517D-C19 260UW 3.73MHZ LASER HEAD ASML
ASML IMAGE SENSOR 3652513 PN 4022.454.08271 IS DETECTOR CALIBRATION PLATE
ASML 859-9969-001 RETICLE, MICRASCAN II, 4X 859-0028-802
ASML 4022.455.9427 Control Module With Phase Modulator for ASML Green Laser
ASML agilent z4203d, sold as is, no return
ASML, 4022.639.92101
ASML 4022.428.14590 TB 2500 R PCB Card 4022.428.1459 PAS 50002500 Working
ASML 4022.644.40322 Wafer Handling Tool
ASML 2500 5000 PSCOPE CAMERA 4022.428.05233 22052358
ASML CyberResearch STC-12-T SVI29 Series 90-S Millipore Pump Controller
ASML PAS2500 STEPPER WAFER FLAT FINDER MOTOR ASSEMBLY 4022.451.4818.
NEW ASML 4022.640.59951
ASML 4022.430.0090.
ASML STEPPER PAS2500 ELLIPTICAL MIRROR I-LINE 4022.431.03721 365NM ELLIPSOIDAL
ASML 4022.471.87587 BOARD FREE SHIP
SILICON VALLEY GROUP SVG 90S Operator Panel Flat Panel ASML HMI USA
18558 ASML MAIN SAFETY MISC RACK(MSMR) S2C-H6RU F202 4022.472.78295
ASML Photoresist lens, sold as is,no return
Asml 4022.480.6766 Optique Article Svg GLP 7123 3-0078





Reviews
There are no reviews yet.