5448-906 Woodward Ship Spare Parts
The 5448-906 is a microprocessor-based digital governor controller produced by Woodward, belonging to its classic 505 series.
It is primarily designed for speed control and protection of steam turbines. Below is a detailed introduction to this product:
I. Product Overview
- Brand and Model: Woodward 5448-906
- Series: 505 Series Digital Governor
- Type: Microprocessor-based controller
- Purpose: Specifically designed for steam turbines to control their speed and provide overspeed protection.

II. Core Functions
- Speed Control:
- 5448-906 Precisely controls the speed of steam turbines by adjusting steam inlet flow.
- Supports single-range or split-range actuators to accommodate turbines of different sizes.
- Overspeed Protection:
- Incorporates triple independent overspeed protection logic to ensure rapid shutdown in case of overspeed, preventing equipment damage.
- Provides an overspeed test button for convenient on-site testing of protection functions.
- Emergency Shutdown:
- Equipped with an emergency stop button for immediate shutdown in emergency situations.
- System Protection:
-
- Automatically switches control modes upon sensor failure to ensure uninterrupted system operation.
- Offers local/remote control priority selection to adapt to different operational scenarios.

-
4.2.1 External current limit reduction test
When a voltage of -10V is applied to the XX terminal of the tested driver, the overcurrent monitoring function of the speed controller becomes ineffective.
According to the current reduction characteristic curve, it can be seen that the maximum output current is limited to 40% Imax. Set the speed setpoint to -5V,
turn on the drive enable for 3 minutes and then turn it off. Measure the waveform of the detection hole, and the Iist amplitude should be 4+0.4V. The “overcurrent”
indicator light is not on. The current reduction characteristic curve is shown in Figure 6.
Figure 6: Current reduction characteristic curve
4.2.2I2t monitoring test
The I2t function approximates the square of the actual current value and integrates the result. If the actual current value is 1.1 times the rated value, the integrator
integrates negatively, otherwise it integrates positively.
The specific test uses a test power board instead of the power module of the driver, closes the corresponding switch, and applies -1V voltage to the XX terminal.
According to the XX characteristic curve, the maximum output current is 100% Imax. In this testing interface, the speed is set to -5V, the drive is enabled to open,
and the waveform of W-hole Iist is measured. The recorded data is input into the corresponding unit, and the backend software can provide a conclusion on whether it is qualified or not
through calculation (the final trend of Iist amplitude decrease should be 1.1IN, and the maximum amplitude holding time T should be).
5. Conclusion
The drive testing system can test the drive in both offline and online states. The testing system can help debugging personnel quickly determine and understand the
status of the drive during debugging or use, and propose solutions. The operation is simple and fast, with good human-computer interaction. The system follows the
principles of generalization, standardization, and modular design, and has good interactivity, portability, and scalability.
The design of this testing system has been completed, providing great convenience for the maintenance and repair of the drive. At the same time, a portable
drive testing system is also under research and design and will be completed soon.
III. Technical Specifications
- Power Supply: 18-32 VDC, supporting 24VDC input.
- Display: Two-line x 24-character LED display for clear indication of operating status and parameters.
- Enclosure: NEMA 4X or IEC 60529 IP56 rated for protection against harsh industrial environments.
- Inputs/Outputs:
- Inputs: 6 programmable current inputs, 16 discrete contact inputs.
- Outputs: 2 actuator outputs, 8 relay outputs, 6 programmable current outputs.
- Communication Interfaces: 5448-906 Supports RS-232, RS-422, and RS-485 hardware interfaces for easy integration with host computers or other devices.
- Software: Equipped with OpView™ and 505View software for parameter configuration, monitoring, and fault diagnosis.
- Operating Temperature: -20 to +60°C (some models support -4 to +140°F).
- Storage Temperature: -40 to +85°C (some models support -40 to +185°F).
- 5448-906 Weight: Approximately 9.11 pounds (4.13 kilograms).
IV. Application Scenarios
- Steam Turbine Control: 5448-906Suitable for steam turbines of various sizes, including industrial steam turbines, small grid turbo-generators, and turboexpanders.
- Single Extraction and Admission Applications: Designed for operating steam turbines in single extraction and/or admission applications.
- On-Site Programming: Allows on-site operators to program and adjust parameters through an integrated operator control panel, adapting to different operating conditions.
V. Product Advantages
- High Reliability:
- Microprocessor-based design ensures precise control and stability.
- Triple independent overspeed protection logic provides multiple layers of safety.
- Flexibility:
- Supports various actuator and sensor configurations to accommodate different turbine models.
- Offers a rich set of input/output interfaces for easy system expansion and integration.
- Ease of Use:
- Two-line x 24-character LED display provides an intuitive operating interface.
- A 30-key multifunctional keyboard simplifies parameter configuration and operation.
- Compatibility:
- Supports multiple communication protocols for easy integration with DCS, PLC, and other systems.
- Provides OpView™ and 505View software for remote monitoring and fault diagnosis.
Woodward ship parts module debugger controller actuator generator set
8915-094 WOODWARD Debugger unit,
5463-598 Woodward turbine controller,
TG-13 Woodward Ship Spare Parts,
5439-929 Woodward turbine controller,
8928-5014 Woodward overspeed protector,
5464-474 WOODWARD Debugger unit,
5415-703 Woodward speed control module,
8200-1204 Woodward speed control module,
5500-134 Woodward speed control module,
EGCP-2 8406-121 Woodward turbine controller,
SVG ASML 879-0605-001 Micrascan PCW Manifold
Philips PG2026 CPU PCB Card ASML 4022.230.0332 PAS 50002500 Wafer Stepper
ASML 854-9527-003 RETICLE FIELD DEFINING MSX
ENTERPRISE 610 ARGON ION LASER CONTROLLER ASML MICRASCAN SVG COHERENT LASERS
ASML HEIDENHAIN 4022.640.59951
ASML 859-9633-001 RETICLE FOCUS SEM
SVG JDS Uniphase ASML 4022.455.09864 Green Laser Head with Controller
1PS HIB293 ID 630820-03 L12 ASML 4022.640.59951 (3-month warrantySHIP FedEx)
ASML 4022.639.86653 Class 3B ( AIGaAs ) 850um 10mW Solid state Laser Module
ASML 4022.472.20913 4022.472.20884 4022.470.23341 SEM-I-559=9A39
8 Inch wafer chuck ASML SVG Silicon Valley Group wafer grindingcoati
ASML YMCR 4022.640.75531 , 4022.636.35151 , REXROTH R911171945 YS MOTION RACK
ASML 4022.639.86653 IR2-FIR Solid State Laser Module 850nm ELEC-I-1054=9A
ASML 4022.634.38371 SUPPLY UNIT PAAC 550255,
ASML RS XTIV X-AIRBEARING for parts 4022.666.42241 SEM-I-980=9G22
SVG ASML 879-0794-001 Micrascan, Axiom Assembly
SVG – Silicon Valley Group, Inc 879-8234-007 ASML
Philips PG 2024 CPU PCB Card ASML PAS 50002500 Wafer Stepper System
ASML PN: 4022.428.1094
ASML MHB3 PPCA 4022.471.75263
ASML 4022.480.72822 4022.470.15191