TG-13(8516-038) Woodward turbine controller
The TG-13(8516-038) is a microprocessor-based digital governor controller produced by Woodward, belonging to its classic 505 series.
It is primarily designed for speed control and protection of steam turbines. Below is a detailed introduction to this product:
I. Product Overview
- Brand and Model: Woodward TG-13(8516-038)
- Series: 505 Series Digital Governor
- Type: Microprocessor-based controller
- Purpose: Specifically designed for steam turbines to control their speed and provide overspeed protection.

II. Core Functions
- Speed Control:
- TG-13(8516-038) Precisely controls the speed of steam turbines by adjusting steam inlet flow.
- Supports single-range or split-range actuators to accommodate turbines of different sizes.
- Overspeed Protection:
- Incorporates triple independent overspeed protection logic to ensure rapid shutdown in case of overspeed, preventing equipment damage.
- Provides an overspeed test button for convenient on-site testing of protection functions.
- Emergency Shutdown:
- Equipped with an emergency stop button for immediate shutdown in emergency situations.
- System Protection:
-
- Automatically switches control modes upon sensor failure to ensure uninterrupted system operation.
- Offers local/remote control priority selection to adapt to different operational scenarios.

-
PLC controllers usually consist of two parts: hardware and software, so these two aspects need to be considered when repairing PLC controllers.
Hardware maintenance:
Check power supply: Check whether the power supply of the PLC controller is normal, including whether the input voltage is stable,
whether the power cord is plugged in properly, and whether the power switch is turned on.
Check input/output module: Check if the input/output module is plugged in properly and if the signal lines are connected correctly.
Replace faulty components: Based on the fault symptoms and possible causes, replace corresponding components such as capacitors, resistors, relays, etc.
Cleaning internal components: Clean the components inside the PLC controller to prevent component aging, contamination, and corrosion.
Software maintenance:
Check the program: Check whether the PLC controller program is correct, including whether the instructions are incorrect,
whether the logical relationships are correct, etc.
Replace program memory: If the program memory fails, you can try replacing it with a new one.
Reinstall program: If the program encounters serious errors, you can try reinstalling the program.
Clean up storage: Clean up useless data and programs in the storage to free up storage space.
When repairing a PLC controller, it is necessary to first understand the fault symptoms and possible causes, and then gradually eliminate the possible fault points.
If you are unable to solve the problem on your own, you can seek professional technical support or repair services.
III. Technical Specifications
- Power Supply: 18-32 VDC, supporting 24VDC input.
- Display: Two-line x 24-character LED display for clear indication of operating status and parameters.
- Enclosure: NEMA 4X or IEC 60529 IP56 rated for protection against harsh industrial environments.
- Inputs/Outputs:
- Inputs: 6 programmable current inputs, 16 discrete contact inputs.
- Outputs: 2 actuator outputs, 8 relay outputs, 6 programmable current outputs.
- Communication Interfaces: TG-13(8516-038) Supports RS-232, RS-422, and RS-485 hardware interfaces for easy integration with host computers or other devices.
- Software: Equipped with OpView™ and 505View software for parameter configuration, monitoring, and fault diagnosis.
- Operating Temperature: -20 to +60°C (some models support -4 to +140°F).
- Storage Temperature: -40 to +85°C (some models support -40 to +185°F).
- TG-13(8516-038) Weight: Approximately 9.11 pounds (4.13 kilograms).
IV. Application Scenarios
- Steam Turbine Control: TG-13(8516-038)Suitable for steam turbines of various sizes, including industrial steam turbines, small grid turbo-generators, and turboexpanders.
- Single Extraction and Admission Applications: Designed for operating steam turbines in single extraction and/or admission applications.
- On-Site Programming: Allows on-site operators to program and adjust parameters through an integrated operator control panel, adapting to different operating conditions.
V. Product Advantages
- High Reliability:
- Microprocessor-based design ensures precise control and stability.
- Triple independent overspeed protection logic provides multiple layers of safety.
- Flexibility:
- Supports various actuator and sensor configurations to accommodate different turbine models.
- Offers a rich set of input/output interfaces for easy system expansion and integration.
- Ease of Use:
- Two-line x 24-character LED display provides an intuitive operating interface.
- A 30-key multifunctional keyboard simplifies parameter configuration and operation.
- Compatibility:
- Supports multiple communication protocols for easy integration with DCS, PLC, and other systems.
- Provides OpView™ and 505View software for remote monitoring and fault diagnosis.
Woodward ship parts module debugger controller actuator generator set
9700-1200 Woodward Ship Spare Parts,
5461-062 Woodward ProTech 203,
9907-1183 Woodward turbine controller,
5441-663 Woodward Ship Spare Parts,
5453-203 Woodward turbine controller,
5441-673 Woodward overspeed protector,
5437-078 Woodward ProTech 203,
8270-122 WOODWARD Debugger unit,
5441-697 Woodward speed control module,
5463-716 Woodward ProTech 203,





Reviews